Reservoirs and reservoir parts

Description

Part No.

Reservoir, 1 L, including cap

2270.0012

Reservoir, 0.25 L, including cap

2270.0026

Cap for reservoirs, screw-cap (pack of 4)

6270.0013

Cap plug to close open holes in the reservoir cap (pack of 20)

6000.0047

Retaining guide (diameter 1.6 mm) to keep the following lines in the reservoir caps (pack of 5):

  • Solvent lines (reservoir to pump)

  • Wash lines (reservoir to degasser in pump and reservoir to autosampler wash pump)

6261.0216

Retaining guide (diameter 3 mm) to keep the seal wash line in the reservoir caps (pack of 5)

6000.0042

Plugs and retaining guides (diameter 1.6 mm) for seal wash reservoir caps, kit including

  • Cap plug to close open holes in the reservoir cap (pack of 10)

  • Retaining guide for seal wash reservoir line, to keep the seal wash line in place in the reservoir cap (pack of 5)

6030.9101

Solvent lines, wash reservoir lines, and solvent line filters

Description

Part No.

Solvent and wash lines kit for inner and outer needle wash, including reservoir lines and labels for solvents

6250.2305

Solvent lines (A, B) from solvent reservoirs to pump inlet

6251.0096

The Low-Pressure Tubing Kit for the pump also includes solvent lines. See Pump Replacement Parts.

Solvent line filter, filter holder (pack of 6)
(no filter frits or solvent line adapter included)

6268.0115

Solvent line adapter (1/8-1/16) (pack of 6)

6850.1056

Solvent line filter, filter frit, biocompatible, 10 µm (pack of 10)

6268.0117

Tubing and parts for wash systems

Description

Part No.

Peristaltic and wash tubing kit

The kit includes peristaltic tubing (PharMed), silicone tubing, and tubing connectors for use in

  • Seal wash system in the pump and in the autosampler

  • Drain pump in the autosampler

NOTICE: Use the thick silicone tubing (and related tubing connectors) in the autosampler. Use the thin silicone tubing (and related tubing connectors) in the pump. Use the screwable connectors for the pump head.

6044.1150

Seal wash detector (drop detector) with funnel

6044.1898A

VN rear sealing and screws kit (VN pump), seal wash plate/pump head, including:

  • Pump head seal, for seal wash plate (O-ring seal, 11x1.5) (2 seals)

  • Pump head seal, for seal wash plate screw (O-ring seal, 6.5x1) (8 seals)

  • Screw, seal wash plate (8 screws)

6251.2234

Piston seal (RP) and seal wash seal, pump head (pack of 2 each)

6251.1143

Needle wash PEEK kit, including

  • Wash port waste PEEK capillary (2 pieces)

  • Connection from wash pump outlet to wash port

6252.1930