Replacing the Pre-heater - Column Compartment H - Column Compartment C - Vanquish Column Compartments (VC-C10, VH-C10) Operating Manual - Maintenance and Service - Replacing the Pre-heater - Column Compartment H - Column Compartment C

Vanquish Column Compartments (VC-C10, VH-C10) Operating Manual

Product Tree
Chromatography > Liquid Chromatography > Vanquish Series > Vanquish Horizon UHPLC > Column Compartment H
Chromatography > Liquid Chromatography > Vanquish Series > Vanquish Core HPLC > Column Compartment C
Document Type
Operating Manual
  • Vanquish Column Compartments
  • Using this Manual
  • About this Manual
  • Conventions
  • Conventions for Safety Messages
  • Special Notices
  • Typographical Conventions
  • Reference Documentation
  • Safety
  • Safety Symbols and Signal Words
  • Safety Symbols and Signal Words in this Manual
  • Observing this Manual
  • Safety Symbols on the Device
  • Rating Plate
  • Intended Use
  • Safety Precautions
  • General Safety Information
  • Qualification of the Personnel
  • Personal Protective Equipment
  • Electrical Safety Precautions
  • General Residual Hazards
  • In Case of Emergency
  • Solvent and Additive Information
  • General Compatibility
  • Allowed pH Ranges
  • Allowed Concentrations
  • Further Information
  • Compliance Information
  • Device Overview
  • Column Compartment Features
  • Operating Principle
  • Interior Components
  • Leak Detection
  • Column Identification (Column ID)
  • Operation
  • Unpacking
  • Unpacking the Device
  • Scope of Delivery
  • Installation
  • Safety Guidelines for Installation
  • Installing the Device
  • Site Requirements
  • Power Considerations
  • Power Cord
  • Condensation
  • Accessing the Interior Components
  • Setting Up the Hardware
  • System Arrangement
  • Attaching the Column Compartment to the System
  • Guiding Liquids to Waste
  • Connecting the Device
  • Connecting the Power Cord
  • Installing the Post-Column Cooler (VH-C10 only)
  • Installing the Passive Pre-Heater
  • Installing the Column Switching Valve
  • Installing Column Identification (Column ID)
  • Setting Up the Flow Connections
  • General Information and Guidelines
  • Connecting Fittings, Capillaries, and Tubing
  • General Guidelines
  • Connecting Viper Capillaries
  • Connecting and Placing the Column
  • Connecting and Placing the Active Pre-heater
  • Connecting the Components to a Column Switching Valve
  • Fluidic Setup for the Use of One Column Switching Valve
  • Fluidic Setup for the Use of Two Column Switching Valves
  • Turning On the Device
  • Setting Up the Device in the Software
  • Operation
  • Introduction to this Chapter
  • Safety Guidelines for Operation
  • Control Elements
  • Keypad
  • Status Indicators
  • Power On/Off Control
  • Preparing the Device for Operation
  • Important Operating Parameters
  • Ready Temp Delta and Equilibration Time
  • Optimizing the Performance of the Device
  • General Guidelines
  • Active Pre-Heating
  • Shutting Down the Device
  • Short-Term Shutdown (Interruption of Operation)
  • Long-Term Shutdown
  • Restart after Long-Term Shutdown
  • Maintenance and Service
  • Introduction to Maintenance and Service
  • Safety Guidelines for Maintenance and Service
  • General Rules for Maintenance and Service
  • Routine and Preventive Maintenance
  • Maintenance Plan
  • Cleaning or Decontaminating the Device
  • Predictive Performance
  • Column Switching Valve
  • Inspecting the Column Switching Valve for Leakage
  • Replacing the Column Switching Valve
  • Replacing the Column Switching Valve Cover
  • Replacing the Post-Column Cooler (VH-C10 only)
  • Replacing the Pre-heater
  • Replacing the Active Pre-Heater
  • Replacing the Passive Pre-Heater
  • Replacing the Main Power Fuses
  • Replacing the Device Door
  • Updating the Device Firmware
  • Transporting or Shipping the Device
  • Preparing the Device for Transport
  • Transporting the Device to a New Location
  • Shipping the Device
  • Troubleshooting
  • General Information about Troubleshooting
  • Messages
  • Resolving Liquid Leaks
  • Specifications
  • Performance Specifications
  • Physical Specifications
  • Accessories, Consumables and Replacement Parts
  • General Information
  • Ship Kit
  • Optional Accessories
  • Consumables and Replacement Parts
  • Appendix
  • Compliance Information
  • Declarations of Conformity
  • WEEE Compliance
  • FCC Compliance
  • Manual Release History

This section describes how to replace a pre-heater in the column compartment. Depending on the configuration of the column compartment, different types of pre-heaters are available.

  • Active pre-heater, see Replacing the Active Pre-Heater.

  • Passive pre-heater, see Replacing the Passive Pre-Heater.

Back to home page