Part number | Description |
|---|---|
Eluent storage and delivery | |
B51001953 | Digital regulator display |
B51001954 | Digital regulator |
22185-40210 | Routing tubing clip |
22185-62706 | Dionex Inuvion Digital Regulator Kit |
22185-62707 | Eluent monitor for 2-liter eluent bottle |
22185-62708 | Eluent monitor for 4-liter eluent bottle |
045987 | Filter, end-line |
062510 | Eluent bottle (polypropylene), 2 L |
063292 | Eluent bottle (polypropylene), 4 L |
074505 | Filter, high-pressure inline |
088467 | Carbonate mixer, 2 mm |
088468 | Carbonate mixer, 4 mm |
088471 | Dionex EPM 500 Electrolytic pH Modifier |
Pump head components | |
B51000563 | Piston seal (rear), 1/8-in |
B51001290 | Low-pressure valve, 3 ports |
B51002398 | Pump head assembly |
B51002818 | O-ring, 32-mm ID x 35-mm OD |
B51002819 | O-ring, 11-mm ID x 14 mm-OD |
045994 | Check valve cartridge |
22185-20206 | Outlet check valve holder |
22185-20207 | Inlet check valve holder |
22185-20210 | Pump head seal installation tool |
22185-60147 | Pressure damper |
22185-60206 | Pressure transducer |
22185-62701 | Dionex Inuvion Seal Wash Kit |
22185-63027 | Shutoff valve |
22185-98201 | Duron seal, 1/8-in |
048722 | Piston rinse seal |
22185-98202 | Piston |
055752 | O-ring for waste valve or priming valve |
Eluent generator consumables | |
106-60001 | Dionex Inuvion RFIC Degasser |
22185-40701 | Cradle for Dionex Carbonate Removal Device (CRD) |
075778 | Dionex EGC 500 KOH Potassium Hydroxide Eluent Generator Cartridge |
075779 | Dionex EGC 500 MSA Methanesulfonic Acid Eluent Generator Cartridge |
088453 | Dionex EGC 500 K2CO3 Potassium Carbonate Eluent Generator Cartridge |
060610 | EGC Vent Line Assembly |
303057 | EGC Vent Line Adaptor, Elbow |
088467 | Dionex EGC 500 Carbonate Mixer Kit for 2 mm columns |
088468 | Dionex EGC 500 Carbonate Mixer Kit for 4 mm columns |
Injection valve and sample loop | |
016388 | Syringe, 1 mL (for manual injections) |
024305 | Luer adapter fitting, 1/4-28 (for manual injections) |
030391 | Sample loop, 100 μL |
042857 | Sample loop, 25 μL |
042949 | Sample loop, 10 μL |
075973 | Valve Rebuild Kit (for 6-port valve) |
079054 | Valve Rebuild Kit (for 10-port valve) |
079803 | Syringe, 10 mL (for priming eluent lines) |
Auxiliary valve (not available for reorder) | |
22185-62703 | High Pressure Auxiliary Valve Kit (for 10-port valve) |
22185-62704 | High Pressure Auxiliary Valve Kit (for 6-port valve) |
Suppressors, cell, and column heater | |
B51001284 | Regeneration pump tube |
B51002403 | Conductivity detector cell |
B51004248 | Column heater heat exchanges, 1/16-in OD tubing |
B51004249 | Column heater heat exchanges, 1/32-in OD tubing |
22153-40025 | Column holder clip |
22185-62400 | Column oven |
22185-62700 | Trap column clip |
22185-62702 | Regenerant pump |
085028 | Dionex AERS 500 Carbonate Electrolytically Regenerated Suppressor (2 mm) |
085029 | Dionex AERS 500 Carbonate Electrolytically Regenerated Suppressor (4 mm) |
085090 | Dionex ACRS 500 Anion Dynamically Regenerated Suppressor (4 mm) |
085091 | Dionex ACRS 500 Anion Dynamically Regenerated Suppressor (2 mm) |
085092 | Dionex CCRS 500 Cation Dynamically Regenerated Suppressor (4 mm) |
085093 | Dionex CCRS 500 Cation Dynamically Regenerated Suppressor (2 mm) |
088662 | Dionex CR-ATC 600 Continuously Regenerated Trap Column |
088663 | Dionex CR-CTC 600 Continuously Regenerated Trap Column |
088666 | Dionex ADRS 600 Anion Dynamically Regenerated Suppressor (4 mm) |
088667 | Dionex ADRS 600 Anion Dynamically Regenerated Suppressor (2 mm) |
088668 | Dionex CDRS 600 Cation Dynamically Regenerated Suppressor (4 mm) |
302661 | Dionex AERS 500e Electrolytically Regenerated Suppressor (4 mm) |
302662 | Dionex AERS 500e Electrolytically Regenerated Suppressor (2 mm) |
Fittings | |
22000-9801 | Fitting bolt, 10-32, for double-cone ferrule fitting |
024305 | Luer adapter fitting, 1/4-28 |
039056 | Fitting coupler, 1/4-28 |
042627 | Fitting coupler, 10-32 |
042772 | Fitting plug, 10-32 |
042806 | Fitting coupler, 1/4-28 to 10-32 |
043276 | Ferrule fitting, 10-32 double-cone |
048949 | Ferrule fitting, 1/8 in |
052230 | Fitting bolt, flangeless, 1/16 in |
052276 | Fitting nut, flangeless, 1/8 in |
057934 | Fitting bolt, flangeless, 1/8 in |
062511 | Ferrule fitting, flangeless, 2-piece, 1/16 in |
IC PEEK Viper fittings and tubing assemblies | |
B51000230 | Viper assembly, 0.18-mm (0.007-in) ID, 140 mm (5.5 in) long |
B51000232 | Precision Viper Kit |
B51000233 | Viper assembly, 0.18-mm (0.007-in) ID, 76 mm (3 in) long |
B51000237 | Viper assembly, 0.18-mm (0.007-in) ID, 203 mm (8 in) long |
Miscellaneous | |
22185-60201 | Optical leak sensor |
960777 | USB cable, 1.8 m (6 ft) |
Preventive Maintenance Kit | |
B51001547 | Dionex Inuvion Preventive Maintenance Kit |
062823 | Next Due Date label |