In the Compound Discoverer application, data processing takes place within the study environment. To create a practice study, use the example Thermo Scientific™ Xcalibur™ RAW files that are provided in the following folder in the Compound Discoverer media kit, which is available on the Compound Discoverer USB flash drive or via the Thermo Fisher SW Download Portal: Example Studies\LC\Stable Isotope Labeling
NOTE
The Life Sciences Mass Spectrometry Software Download and Licensing Portal (Flexnet Operations portal or Flexera) is changing to a new Thermo Fisher Download Portal that will require each customer to have an account. If you have an existing Thermo Fisher portal account, you do not need to create a new one. If you navigate to the original Flexnet Operations link, you will be automatically redirected to the new URL for the Thermo Fisher Download Portal.
To access the example files on the Thermo Fisher Download Portal, do the following:
Procedure
- Open the SW Download Portal at https://thermofisher.com/download.
- Enter your login ID and password (you will need to register on the first use).
- Navigate to Application – Compound Discoverer on the home page or select Product Search.
- If using Product Search, enter Compound Discoverer 3.5.
- Select the row for Compound Discoverer 3.5.
- Download the appropriate Thermo Compound Discoverer 3.5 example files.
File name | File type |
|---|---|
Blank_01.raw | RAW file |
Ecoli_12C_01.raw | RAW file |
Ecoli_12C_02.raw | RAW file |
Ecoli_12C_03.raw | RAW file |
Ecoli_13C_01.raw | RAW file |
Ecoli_13C_02.raw | RAW file |
Ecoli_13C_03.raw | RAW file |
Ecoli_12C_AcquireX_ID_01.raw | RAW file |
Ecoli_12C_AcquireX_ID_02.raw | RAW file |
Ecoli_12C_AcquireX_ID_03.raw | RAW file |
Ecoli_12C_AcquireX_ID_04.raw | RAW file |
Stable Isotope Labeling.cdResult | Result file (analysis result) |
Stable Isotope Labeling.cdStudy | Study file |
IMPORTANT
For optimal performance, it is recommended to store all Compound Discoverer study files (.cdStudy) and result files (.cdResult) on a local hard drive, ideally a solid-state drive (SSD). External USB-connected hard drives and network drives typically have slower read and write speeds and latency than internal hard drives.
Because the result file is continuously accessed throughout the entire data processing workflow, using external drives can significantly increase processing times. Unlike result files, the application reads the raw data files (input files) only once, at the very beginning of the processing workflow. Therefore, you can store raw data files on an external drive without significantly increasing the processing time.