The following table defines the columns in the Ardia Repository.

NOTE

The date and time format, as well as the number and list separators in the Data Explorer application, are determined by either your browser's regional settings or your preferences in User Settings. For more information, see Change the date and time settings and Change the list and decimal separators.

Parameter

Description

Folder columns

#

Displays the row number. The row numbers are independent of the row content, so they remain unchanged during sorting.

The row numbers do not appear in the search results.

Name

Displays the name of the item in the Ardia Repository.

Version

Displays the version number of the item.

Type

Indicates the category of the item.
Examples: Folder, Sequence, Audit Query, Peptide Experiment, and so on.

Size

Displays the size of the file.

Date Modified

Specifies the date and time when the item was last modified.

Modified By

Displays the username of the last person to modify the item and save the change.

Status

Displays the current status of the item. The status of the item can be one of the following:

Proteins

Specifies the number of high-confident protein IDs.

Peptide groups

Specifies the number of high-confident peptide IDs.

PSMs

Specifies the number of high-confident PSMs.

MS/MS spectra

Specifies the number of MS/MS spectra.

Sequence columns

#

Displays the order number of injections within the sequence. For directly acquired data, this represents the order of execution. For uploaded data, it reflects the order in which files were uploaded to the Ardia Repository.

The order numbers do not appear in the search results.

Name

Displays the name of the item in the Ardia Repository.

Note: icon appears next to the name of any raw data file that fails background verification. For more information, see Raw data file verification.

Type

Displays the type of sample used for the injection.
Examples: Unknown, Blank, Calibration standard, Quality Check and so on.

Position

Specifies the position in which the sample is placed in the autosampler.

Acquisition Status

Displays the status of the acquisition process.

Inject Time

Specifies the date and time when the data was acquired.

Size

Displays the size of the file.

Upload Status

Displays the status of the background raw data verification. The status of an item can be one of the following:

  • : Background raw data verification is successful.
  • : Raw data verification failed.
  • The system detected corruption or modifications in the raw data that occurred between the time of acquisition and the time of verification.
  • For more information, see Raw data file verification.

NOTE: Pointing to the icon displays a tooltip about the verification failure.

To know more about the background raw data verification, see the Raw Data section of the table in Ardia Core settings parameters.

Result Path